HOME  |  PROFILE  |  CONTACT US  
Welcome to Tracom
Tracom was founded in 1987 as a Marketing Company. In 1988, the Company made an entry into Dental Profession and since then is involved in Sales and Marketing of Dental Equipments, Instruments and Materials in the territory of India.
read more....
Company Wise  
- Self Etch Vs. Total Etch
- MDP Monomer
- Clearfil SE Bond
- Clearfil AP-X
- Clearfil AP-X Esthetics
- Panavia-F
- Clearfil Photocore
- Caries Detector
- Alloy Primer
- Clearfil Ceramic Primer
- K-Etchent Gel
- Teethmate F-1
- Soaric
- Signo G10
- TwinPower Ultra Series
- Lubrina
- Veraviewepocs 3D R100
- Veraview iX
- Root ZX mini
- Tri Auto mini
- Dentaport ZX
- Tri Auto ZX
- Endowave
- Vitapex
- SB Post
- GP Solvent
- Free Access
- Pencure 2000
- Prep Start
- H2O Accessories
- Micro Etcher
- Contact Matrix
- Contact Wedges
- Ice Light Post
- Star Flow
- Flash Buster
- Spin Bright
- Trimeze
- Retract
- SuperEndo Alpha
- SuperEndo Beta
- Ultrasonic Endodontic Tip
- Ultrasonic Microsurgical
     Tip

- Vibra Post Tip
- Microsurgical Instrument
- Implant Scaler Tip
- Ultrasonic Tip for Scaling
- WhiteStar Diode Laser
- No-Contact Handpiece
- Laser Bleaching Gel
- Flour Gel for
     Hypersensitivity

- ENT Laser

- Easy-Filler
- FISIOGRAFT   nanoH.A.reinforced
- Chlo-Site

- Obtura
- Obtura S Kondensors
- Multi Task System (MTS)
- CPR Titanium Tips
- CPR Diamond Tips
- BUC Tips
- SL Restorative Tips
- KiS Microsurgical Tips
- PST Tips
- Multi Task Cart
- Microsurgical Instruments
Specilalties Wise Products

- Clearfil SE Bond
- Clearfil AP-X Esthetics
- Clearfil Ceramic Primer
- Panavia-F
- H2O Accessories
- Dentaport ZX
- Self Etch Vs. Total Etch
- Clearfil Photocore
- MDP Monomer
- Alloy Primer
- Clearfil Repair System
- K-Etchant Gel
- Vitapex
- SB Post
- GP Solvent
- Free Access
- Jetlight 4000+
- Starflow
- Ice Light Post
- Contact Matrix
- Contact Wedges
- Contact Rings
- Micro Etcher
- Flash Buster
- Spin Bright
- Air Abrasion System
- Trimeze
- WhiteStar Diode Laser
- Retract
- Root ZX mini
- Tri Auto mini
- Tri Auto ZX
- Rotory Master
- Dentaport
- Endowave
- SuperEndo Alpha
- SuperEndo Beta
- Ultrasonic Endodontic Tip
- Ultrasonic Microsurgical
     Tip

- Vibra Post Tip
- Microsurgical Instrument
- Implant Scaler Tip
- Ultrasonic Tip for Scaling
- Obtura
- Multi Task System
- Starflow
- H2O Accessories
- Micro Etcher
- Flash Buster
- WhiteStar Diode Laser
- Free Access
- Panavia - F
- Clearfil Photocore
- Clearfil Ceramic Primer
- H2O Accessories
- Self Etch Vs. Total Etch
- MDP Monomer
- Alloy Primer
- Clearfil Repair System
- Clearfil ST Opaquer
- K-etchent
- Fisiograft
- SB Post
- Free Access
- Jegtlight 4000+
- Miratom Trays
- Ice Light Post
- Micro Etcher
- Flash Buster
- Spin Bright
- Trimeze
- WhiteStar Diode Laser
- Retract
- DNA / RNA Finder
- Chlo-Site
- WhiteStar Diode Laser
- Trimeze
- Teethmate F-1
- Clearfil SE Bond
- Clearfil AP-X Esthetics
- H2O Accessories
- Dentaport ZX
- Self Etch Vs. Total Etch
- MDP Monomer
- Panavia-F
- K-etchent
- Root ZX MINI
- Tri Auto ZX
- Dentaport
- Endowave
- Vitapex
- GP Solvent
- Free Access
- Jetlight 4000+
- Starflow
- Contact Matrix
- Contact Wedges
- Contact Rings
- Micro Etcher
- Flash Buster
- Spin Bright
- Air Abrasion System
- Trimeze
- Retract
- Premium Line Pliers
- EQ Line Pliers
- Spot Welders
- WhiteStar Diode Laser
- Dyanamics of Ortho
- Fisiograft
- Chlo-Site
- Free Access
- Trimeze
- WhiteStar Diode Laser
- Retract
 
   


SEM
: culture of osteoblasts on nanohydroxyapatite

For years, polylactic and polyglycholic copolymers, dextran and polyethylene glycol have been the components used in Fisiograft, a space maintainer utilized for guided regeneration of bone tissue.

The nanohydroxyapatite used in FISIOGRAFT nanoH.A.reinforced is synthesized using a technique developed by Ghimas S.p.A. to produce granules with dimensions between 70 and 100 nanometers

Use nanotechnology of the future… today!

Osteoblasts adhere and proliferate optimally on the nanohydroxyapatite

This is the only nanohydroxyapatite that has structural, dimensional and biofunctional characteristics that replicate those of the natural hydroxyapatite present in the cementum and bone.
The granules of nanohydroxyapatite-dextran are smoothened to eliminate any sharp angles which may form after the granules are crushed, afterwards they pass through a calibrated filter to select particles with dimensions between 500 and 750 μm.
Biomimicry and biofunctionality

The hydroxyapatite produced by the osteoblasts joins with the nanohydroxyapatite.

From a biological point of view, the rounded form of the granules is determinant since it improves the biofunctionality of the osteogenic cells, which show a preference for rounded surfaces.

Thanks to the characteristics of the nanometric dimension, the nanohydroxyapatite functions as a nucleus for the aggregation of hydroxyapatite produced first by the osteoblasts and then by the osteocytes.

Certainty with the results
  • taken at the implant site 4 months after a
  • major lift of the maxillary sinus shows: 100%
  • 42% of neoformed bone, of new bone
  • 21% of nanohydroxyapatite
  • 37% medullary spaces.

 

FISIOGRAFT nanoH.A.reinforced In Ready –to-use syringe


SEM photograph FISIOGRAFT nanoH.A.reinorced
The components of FISIOGRAFT nanoH.A.reinforced
•a portion is partially absorbed to leave space for new bone: the polylactic and polyglycolic  copolymers undergo hydrolysis and are degraded over a period of time (3-6 months), the  dextran and polyethylene glycol are removed from the site by organic fluids within 7-15 days;
•the portion that is not absorbed, goes on to become nuclei of ossification for the  hydroxyapatite produced by the osteoblasts: in fact, the particles of nanometric  hydroxyapatite, for their dimensional and chemical-physical characteristics, remain at the site  and constitute aggregation points for the hydroxyapatite produced by the osteoblasts, until  they are completely incorporated by new bone.
Method of application:
The syringe of FISIOGRAFT nanoH.A.reinforced is ready for use and does not require any preparation
indications  
mplantology
  > Post extraction sites
  >Dehiscences and bone defects
  >Major and minor augmentations of the maxillary sinus
Periodontology
   > Filling of pockets with one or two walls
  >Treatment of grade II forcation defects

In all the applications, fill the defect with Fisiograft nanoH.A.reinforced bycompacting it, but not excessively

Post extraction alveoli 3.5 and 3.6.
The yellow color is due to washing
with tetracycline.

Filling is facilitated by the ready-touse
syringe of FISIOGRAFT nanoH.A.reinforced

Material in position before being
compacted into the alveoli

Additional filling of the defect.
The syringe makes filling the site
very simple and easy.

(Photos courtesy of dr. Bo)

The ready-to-use syringe of FISIOGRAFT nanoH.A.reinforced permits the product to be easily applied. The granules remain in position facilitating the surgical phases.

Clinical case of a surgical procedure for treating bone defects


Rx Grade II forcation at 4.6

Probing the grade II forcation


Application of
Fisiograft nanoH.A.reinforced


Rx Control at 3 months
(Photos courtesy of prof. Andrea Pilloni and dr. Dominici)

A radiological control made only 3 months after the surgery shows in the forcation defect a pronounced radio-opacity. FISIOGRAFT nanoH.A.reinforced induced bone neogenesis even in this serious case of an advanced Grade II B class forcation.
 

Clinical case of a maxillary sinus floor elevation


Rx pre-operatory

Filling with
Fisiograft nanoH.A.reinforced


Rx Control at 4 months
 
(Photos courtesy of Dr. Andrea Samori)

Application of the material facilitated by the ready-to-use syringe of FISIOGRAFT nanoH.A.reinforced (generally 2-3 syringes of product are needed), permits accelerating the surgical
phases. OPM at 4 months shows the successful bone neogenesis of the floor of the sinus.



Rx pre-operatory

Filling with
Fisiograft nanoH.A.reinforced


Rx Control at 4 months

Histology at 4 months of a core


Confirming the evident radiological result, histomorphometric analysis shows the presence of neoformed bone (42%), nanohydroxyapatite (21%) and medullary spaces (37%). This result obtained with FISIOGRAFT nanoH.A.reinforced only 4 months after the surgery is similar to that obtained after 6-8 months with autologous bone or with other space maintainers, as described in the literature 2, 3.


Rx Root fracture at 2.5
with a large circular defect


Rx Control at 3 months

Rx Control at 6 months

Rx control at 9 months:
complete

(Photos courtesy of dr. Vittorio Farina)

The evolution of the radiological picture shows the formation of a progressively increasing radio-opacityat the defect site treated with FISIOGRAFT nanoH.A.reinforced as early as 3 months, with
complete bone regeneration after 9 months

   

 

Fisiograft
Worlds Only Graft
In 3 Forms

  You may like to call us at 011-4057 6270

 

All rights reserved Copyright © Tracom Services Pvt. Ltd. HOME  |  PROFILE  |  CONTACT US
Website powered by  webpix